800.223.0483

Selling exclusively to wholesale electrical distributors.

301-320 of 369 results for C10SC1

Browse Category
NEMA MAGNETICALLY LATCHED LIGHTING CONTACTOR

NEMA MAGNETICALLY LATCHED LIGHTING CONTACTOR

Item Number: A202K1EAM

MAGNETICALLY LATCHED; 5 POLE; 277 VAC LINE TO NEUTRAL/480 VAC LINE TO LINE (FILAMENT LAMP), 600 VAC (BALLAST LAMP); 30 AMPERE; RESISTIVE CURRENT 30 AMPERE AT 480 VAC TUNGSTEN LIGHTING/600 VAC BALLAST LIGHTING; COIL VOLTAGE 110 V AT 50 HZ, 120 V AT 60 HZ

NEMA MECHANICALLY HELD LIGHTING CONTACTOR

NEMA MECHANICALLY HELD LIGHTING CONTACTOR

Item Number: A202K5CAM

MECHANICALLY HELD; 3 POLE; 277 VAC LINE TO NEUTRAL/480 VAC LINE TO LINE (FILAMENT LAMP), 600 VAC (BALLAST LAMP); 300 AMPERE; RESISTIVE CURRENT 300 AMPERE AT 480 VAC TUNGSTEN LIGHTING/600 VAC BALLAST LIGHTING; COIL VOLTAGE 110 V AT 50 HZ, 120 V AT 60 HZ

NEMA MECHANICALLY HELD LIGHTING CONTACTOR

NEMA MECHANICALLY HELD LIGHTING CONTACTOR

Item Number: A202K6CAM

MECHANICALLY HELD; 3 POLE; 277 VAC LINE TO NEUTRAL/480 VAC LINE TO LINE (FILAMENT LAMP), 600 VAC (BALLAST LAMP); 400 AMPERE; RESISTIVE CURRENT 400 AMPERE AT 480 VAC TUNGSTEN LIGHTING/600 VAC BALLAST LIGHTING; COIL VOLTAGE 110 V AT 50 HZ, 120 V AT 60 HZ

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201K3CA

NON REVERSING; 3 POLE; 25 HP AT 208 V 3 PHASE, 30 HP AT 240 V 3 PHASE, 50 HP AT 480/600 V 3 PHASE, 115/230 V 1 PHASE; 90 AMPERE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; OPEN; SIZE NEMA 3; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA; A200 MODEL

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201K5CA

NON REVERSING; 3 POLE; 75 HP AT 208 V 3 PHASE, 100 HP AT 240 V 3 PHASE, 200 HP AT 480/600 V 3 PHASE, 115/230 V 1 PHASE; 270 AMPERE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; AUXILIARY CONTACT 1NO; OPEN; SIZE NEMA 5; NEMA CONSTRUCTION STANDARD

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201K5CW

NON REVERSING; 3 POLE; 75 HP AT 208 V 3 PHASE, 100 HP AT 240 V 3 PHASE, 200 HP AT 480/600 V 3 PHASE, 115/230 V 1 PHASE; 270 AMPERE; COIL VOLTAGE 240 VAC AT 60 HZ; AUXILIARY CONTACT 1NO; OPEN; SIZE NEMA 5; NEMA CONSTRUCTION STANDARD; APPROVAL UL

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201K6CA

NON REVERSING; 3 POLE; 150 HP AT 208 V 3 PHASE, 200 HP AT 240 V 3 PHASE, 400 HP AT 480/600 V 3 PHASE, 115/230 V 1 PHASE; 540 AMPERE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; AUXILIARY CONTACT 1NO; OPEN; SIZE NEMA 6; NEMA CONSTRUCTION STANDARD

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201KACA

NON REVERSING; 3 POLE; 1/3 HP AT 115 V 1 PHASE, 1 HP AT 230 V 1 PHASE, 1-1/2 HP AT 208/240 V 3 PHASE, 2 HP AT 480/600 V 3 PHASE; 9 AMPERE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; OPEN; SIZE NEMA 00; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201K0BA

NON REVERSING; 2 POLE; 1 HP AT 115 V 1 PHASE, 2 HP AT 230 V 1 PHASE, 3 HP AT 208/240 V 3 PHASE, 5 HP AT 480/600 V 3 PHASE; 18 AMPERE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; OPEN; SIZE NEMA 0; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201K0CA

NON REVERSING; 3 POLE; 1 HP AT 115 V 1 PHASE, 2 HP AT 230 V 1 PHASE, 3 HP AT 208/240 V 3 PHASE, 5 HP AT 480/600 V 3 PHASE; 18 AMPERE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; OPEN; SIZE NEMA 0; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201K0CX

NON REVERSING; 3 POLE; 1 HP AT 115 V 1 PHASE, 2 HP AT 230 V 1 PHASE, 3 HP AT 208/240 V 3 PHASE, 5 HP AT 480/600 V 3 PHASE; 18 AMPERE; COIL VOLTAGE 480 VAC AT 60 HZ; OPEN; SIZE NEMA 0; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA; A200 MODEL

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201K0DA

NON REVERSING; 4 POLE; 1 HP AT 115 V 1 PHASE, 2 HP AT 230 V 1 PHASE, 3 HP AT 208/240 V 3 PHASE, 5 HP AT 480/600 V 3 PHASE; 18 AMPERE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; OPEN; SIZE NEMA 0; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201K1BA

NON REVERSING; 2 POLE; 2 HP AT 115 V 1 PHASE, 3 HP AT 230 V 1 PHASE, 7-1/2 HP AT 208/240 V 3 PHASE, 10 HP AT 480/600 V 3 PHASE; 27 AMPERE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; OPEN; SIZE NEMA 1; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201K1CA

NON REVERSING; 3 POLE; 2 HP AT 115 V 1 PHASE, 3 HP AT 230 V 1 PHASE, 7-1/2 HP AT 208/240 V 3 PHASE, 10 HP AT 480/600 V 3 PHASE; 27 AMPERE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; OPEN; SIZE NEMA 1; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201K1CW

NON REVERSING; 3 POLE; 2 HP AT 115 V 1 PHASE, 3 HP AT 230 V 1 PHASE, 7-1/2 HP AT 208/240 V 3 PHASE, 10 HP AT 480/600 V 3 PHASE; 27 AMPERE; COIL VOLTAGE 240 VAC AT 60 HZ; OPEN; SIZE NEMA 1; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA; A200 MODEL

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201K1CX

NON REVERSING; 3 POLE; 2 HP AT 115 V 1 PHASE, 3 HP AT 230 V 1 PHASE, 7-1/2 HP AT 208/240 V 3 PHASE, 10 HP AT 480/600 V 3 PHASE; 27 AMPERE; COIL VOLTAGE 480 VAC AT 60 HZ; OPEN; SIZE NEMA 1; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA; A200 MODEL

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201K1DA

NON REVERSING; 4 POLE; 2 HP AT 115 V 1 PHASE, 3 HP AT 230 V 1 PHASE, 7-1/2 HP AT 208/240 V 3 PHASE, 10 HP AT 480/600 V 3 PHASE; 27 AMPERE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; OPEN; SIZE NEMA 1; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201K1EA

NON REVERSING; 5 POLE; 2 HP AT 115 V 1 PHASE, 3 HP AT 230 V 1 PHASE, 7-1/2 HP AT 208/240 V 3 PHASE, 10 HP AT 480/600 V 3 PHASE; 27 AMPERE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; OPEN; SIZE NEMA 1; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201K2CA

NON REVERSING; 3 POLE; 3 HP AT 115 V 1 PHASE, 7-1/2 HP AT 230 V 1 PHASE, 10 HP AT 208 V 3 PHASE, 15 HP AT 240 V 3 PHASE, 25 HP AT 480/600 V 3 PHASE; 45 AMPERE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; OPEN; SIZE NEMA 2; NEMA CONSTRUCTION STANDARD

NON-REVERSING FRONT CONNECTED CONTACTORS

NON-REVERSING FRONT CONNECTED CONTACTORS

Item Number: A201K2CB

NON REVERSING; 3 POLE; 3 HP AT 115 V 1 PHASE, 7-1/2 HP AT 230 V 1 PHASE, 10 HP AT 208 V 3 PHASE, 15 HP AT 240 V 3 PHASE, 25 HP AT 480/600 V 3 PHASE; 45 AMPERE; COIL VOLTAGE 200 TO 208 VAC AT 60 HZ; OPEN; SIZE NEMA 2; NEMA CONSTRUCTION STANDARD