CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL03C2A2A

ELECTRICALLY HELD; 2 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 30 AMPERE; RESISTIVE CURRENT 30 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 110 V AT 50 HZ, 120 V AT 60 HZ

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL03D1A4A

ELECTRICALLY HELD; 4 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 60 AMPERE; RESISTIVE CURRENT 60 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 110 V AT 50 HZ, 120 V AT 60 HZ

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL03E1A4A

ELECTRICALLY HELD; 4 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 100 AMPERE; RESISTIVE CURRENT 100 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 110 V AT 50 HZ, 120 V AT 60 HZ

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL04D1A3A

MAGNETICALLY LATCHED; 3 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 60 AMPERE; RESISTIVE CURRENT 60 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 110 V AT 50 HZ, 120 V AT 60 HZ

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL04D1ABA

MAGNETICALLY LATCHED; 12 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 60 AMPERE; RESISTIVE CURRENT 60 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 110 V AT 50 HZ, 120 V AT 60 HZ

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL04D1E3A

MAGNETICALLY LATCHED; 3 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 60 AMPERE; RESISTIVE CURRENT 60 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 208 V AT 60 HZ; NEMA 1, IP40

100A - 3POLE MAGNETICALLY LATCHED LIGHTING CONTACTOR

100A - 3POLE MAGNETICALLY LATCHED LIGHTING CONTACTOR

Item Number: ECL04E1A3A

100A 240V CNCTR

200A - 3POLE MAGNETICALLY LATCHED LIGHTING CONTACTOR

200A - 3POLE MAGNETICALLY LATCHED LIGHTING CONTACTOR

Item Number: ECL04F1A3A8

3P 200A CONTACTOR

NEMA FREEDOM LINE ENCLOSED CONTROL

NEMA FREEDOM LINE ENCLOSED CONTROL

Item Number: ECN0141A3A

FULL VOLTAGE, NON REVERSING; 3 POLE; 135 AMPERE; COIL VOLTAGE 110 V AT 50 HZ, 120 V AT 60 HZ; AUXILIARY CONTACT 1NO SIDE MOUNTED; HORIZONTAL/VERTICAL MOUNTING; NEMA 1, IP40; SIZE NEMA 4, FRAME 180 MM; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL03B1H6A

ELECTRICALLY HELD; 6 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 20 AMPERE; RESISTIVE CURRENT 20 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 277 V AT 60 HZ

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL03C1E2A

ELECTRICALLY HELD; 2 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 30 AMPERE; RESISTIVE CURRENT 30 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 208 V AT 60 HZ

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL03C2A3A

ELECTRICALLY HELD; 3 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 30 AMPERE; RESISTIVE CURRENT 30 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 110 V AT 50 HZ, 120 V AT 60 HZ

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL03D1C4A

ELECTRICALLY HELD; 4 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 60 AMPERE; RESISTIVE CURRENT 60 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 440 V AT 50 HZ, 480 V AT 60 HZ

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL04D1A4A

MAGNETICALLY LATCHED; 4 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 60 AMPERE; RESISTIVE CURRENT 60 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 110 V AT 50 HZ, 120 V AT 60 HZ

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL03E1H3A

ELECTRICALLY HELD; 3 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 100 AMPERE; RESISTIVE CURRENT 100 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 277 V AT 60 HZ

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL03F1H3A

ELECTRICALLY HELD; 3 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 200 AMPERE; RESISTIVE CURRENT 200 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 277 V AT 60 HZ

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL04C1A2A

MAGNETICALLY LATCHED; 2 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 30 AMPERE; RESISTIVE CURRENT 30 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 110 V AT 50 HZ, 120 V AT 60 HZ

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL04C1ABA

MAGNETICALLY LATCHED; 12 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 30 AMPERE; RESISTIVE CURRENT 30 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 110 V AT 50 HZ, 120 V AT 60 HZ

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL03B1H3A

ELECTRICALLY HELD; 3 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 20 AMPERE; RESISTIVE CURRENT 20 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 277 V AT 60 HZ

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

CN35 OR A202 ENCLOSED LIGHTING CONTACTOR

Item Number: ECL04D1A2A

MAGNETICALLY LATCHED; 2 POLE; 277 V LINE TO NEUTRAL/480 V LINE TO LINE (FILAMENT LAMP), 600 V (BALLAST LAMP); 60 AMPERE; RESISTIVE CURRENT 60 AMPERE AT 480 V TUNGSTEN LIGHTING/600 V BALLAST LIGHTING; COIL VOLTAGE 110 V AT 50 HZ, 120 V AT 60 HZ